Our test facility offers comprehensive compliance testing for rubber insulated electrical gloves.
Electrical glove testing equipment.
Combination glove sleeve blanket line hose testing equipment.
Check in wash and preliminarily inspection of insulating materials.
All gloves tested by jm test systems include a detailed testing report.
What we offer with your lineman gloves.
Our rubber testing lab provides electrical glove testing services to astm d120 astm f496 standards.
Burlington safety laboratory is your source for linemen s protective equipment.
Check out a few of our popular units here.
Electrical testing of insulated aerial lift devices.
This quick video shows that after a fault in any glove is detected the machine tells you which glove is flawed and then ejects the probe from that particular glove.
We have been serving electric utilities telecommunications companies railroads power line contractors and industrial accounts for more than 30 years.
We not only supply electrical gloves ppe we inspect and test them too.
Insulating gloves and sleeves must be rated for the voltage to which a worker will be exposed phase to ground or phase to phase and marked to indicate their rating.
You can depend on our factory trained and certified technicians to do whatever it takes to keep your employees safe and your equipment serviced so it s ready and in top working.
Here is a video of our ejection style glove tester.
A complete record of the testing is documented on a test result sheet.
Immediately following the failure the machine automatically starts ramping up voltage to test the rest of the gloves on that.
Dival is your one stop shop for all of your arc flash electrical glove and ppe needs.
Gloves sleeves and blankets then undergo an electrical test as specified by the class rating of the item and the astm and osha standards maximum 40kv a c.
How often should i test my voltage rated gloves.
Rubber insulated electrical glove testing.
Jm test systems is fully accredited for testing high voltage rubber protective goods.
Hi grip xtreme 14 high voltage arc tested glove protector 43 99 33 51 tri square big wrench.
Rubber sleeves are tested to astm d1051 astm f496 standards.
Additionally 1910 137 provides specific design care and use requirements for rubber electrical protective equipment.
Misinterpreting the rules requiring dielectric testing of electrical insulating gloves and the corresponding expiration dates can be easy to do use article130 7 c 7 nfpa 70e as a reference we add clarity to this commonly misinterpreted safety requirement.